3P Volume filter VF1 Combi

Integrated filter

Operating principle

  1. As water arrives the level builds up and is equally distributed across the cascade.
  2. Pre cleaning through the cascades. Largest dirt particles are led across the primary filter cascades directly to the sewer.
  3. Pre filtered water then flows over the secondary filter sieve (mesh size 0,65 mm). Due to the special mesh structure of the sieve, any dirt washes directly into the sewer which means the filter is self cleaning, with very low maintenance.
  4. Cleaned water flows to the cistern through the outlet at the bottom of the filter.
  5. Dirt goes to the sewer.

Rainwater filter for installation inside or on the tank. The VF1 Combi has the cleaned water outlet at the bottom of the filter.

Whilst the dirt is washed away sidewards, the bottom cleaned water outlet position makes installing the filter in tanks very easily and practically. Where used before the tank, the Combi gives a high degree of flexibility to the angle of direction of the cleaned water outlet pipe, feeding into the rainwater tank. The VF1 Combi can also be fitted directly to the top surface of the rainwater tank, using a seal we can provide. This means it is acts as a second turret of the tank.

Same functionality as 3P Volume Filter VF1.

Connection capacity according to DIN 1986 for roof areas up to 350 m².

Max. Flow Rate Sieve insert 1,5 l/sec = 5,4 m³ cleaned water per hour.

Height difference between inlet and outlet 300 mm.

The cleaned water can be used in washing machines, toilet flushing and garden watering, in homes, in commerce, in public buildings and in industry.

The filter has to be cleaned depending on the contamination 1 - 2 times during the year.

Technical Data

Filter according to DIN 1989-2, Typ C

Connection inlet: 2 x DN 100
Outlet into tank: DN 100
Outlet into sewer: DN 125

Height difference between rainwater inlet and outlet 300 mm.

Housing material: Polyethylen

Filter cartridge: Stainless steel 1.4301

Mesh size: 0,65 mm

Material Cascade insert: Polyethylen

Weight: 6,2 kg

Filtertest

The average rainfall in Germany is 80% less than 15 l / (sxha), which results in a volume flow of 0.58 l / s with a roof area of ​​387 m².

Pipe diameter: DN 125
max. flow: 11,6 l/s
connectable area at max. 200 l/(sxha): 580 m²
connectable area at max. 300 l/(sxha): 387 m²

Application

3P Volume Filter VF1 combi installed inside a shaft of a plastic tank.

Special installation with Overflow Siphon Mono.

We make planning