How it works:
1.
The rainwater from the drained area is fed
into the inlet, which is at the lower end of
the shaft.
2.
Here, sedimentation of particles,
especially the sand faction and above,
takes place in the hydrodynamic
separator. This is due to turbulent
secondary flows within a radial laminar
flow regime.
3.
The solids are collected via an opening
in the silt trap chamber. This chamber is
a removable container, with a side outlet
port to aid cleaning.
4.
The filter element is located in the middle
of the filter shaft. With this filter element,
the finer particles are filtered from the
upflow of waters. The dissolved pollutants
are precipitated and absorbed and
adsorbed. The filter is easily exchanged,
once exhausted or blocked.
5.
Emergency overflow
6.
Cleaned water outlet, to infiltration
system, rainwater storage tank or
surface water discharge.
of solid particles occurs within a radial flow
regime, characterised by secondary flows.
A settling funnel to the silt trap chamber
entrance ensures sediments are not
re-mobilised. Above the separator are the
filter inserts, which cover the entire diameter
of the unit’s housing. Water flows upwards
through the removable filter element.
As a result of the upward flow of the
filter element, and that the filter remains
saturated, filter clogging by solids is very
limited and slow.
Description:
A specialist rainwater filter, suitable for
installation directly in the ground. Connect-
able areas from 100 to 175m², depending on
filter type.
The HS 400 Filter uses an up-flow process.
This means there is a minimal head drop
across the inlet to outlet.
The cleaned water is of an outstanding
water quality. The rainwater is treated
within the Unit by the following processes:
sedimentation, filtration, adsorption and
precipitation.
The first treatment step takes place in the
Dynamic Separator, where sedimentation
Art.-Nr. 3100420 heavy traffic
Art.-Nr. 3100410 traffic
Art.-Nr. 3100400 roof
Art.-Nr. 3100430 metal
Technical Data:
Rainwater filter complying with DIN 1989-2, Typ B; Connections: DN 100
Housing material: Polyethylene Housing weight: 7 kg Total weight: 37 kg
Material telescopic extension: Polyethylene Weight: 5 kg
Material filter element: Filter substrate Filter element weight: 27 kg
Packing unit Hydrosystem 400:
Pallet: 2 pieces (without telescopic extension)
404
mm
370
mm
310
mm
740
mm
840
mm
1180
mm
Accessories 2:
3
P Filter element
Art.-Nr. 3100425 heavy traffic
Art.-Nr. 3100415 roof / traffic
Art.-Nr. 3100435 metal
Accessory 1:
3
P Telescopic extension Art.-Nr. 1000560
The 3P Hydrosystem 400 is combined with the
3
P telescopic extension (see fig. A, right) for
installation directly into the ground.
Its height can be adjusted from 250 to 750 mm.
Fig. A